促销!

ABB AW501035 ASO550 Reference Electrode for Non-Reservoir-Fed Sodium Analyzer Systems

原价为:$512.00。当前价格为:$480.00。

+ Free Shipping

ABB AW501035 is an ASO550 reference electrode specifically identified for non-reservoir-fed systems. ABB documentation lists AW501035 as a spare part for the ASO550 sodium analyzer wet section and distinguishes it from AW501036, which is the reference electrode for reservoir-fed systems. The reference electrode forms an essential part of the electrochemical measurement arrangement used for sodium analysis, providing the reference potential required by the measurement system. AW501035 is associated with ABB’s Navigator 500 sodium analyzer platform and belongs to the continuous liquid analysis and sodium measurement application area. Unlike the sodium sensing electrode, which responds to the sodium concentration in the sample, the reference electrode provides the stable reference required for reliable electrochemical measurement. The non-reservoir-fed designation is an important identification characteristic because the ASO550 platform has separate reference-electrode configurations for reservoir-fed and non-reservoir-fed arrangements. ABB’s ASO550 operating instructions list AW501035 as the “ASO550 reference electrode for non reservoir-fed systems” and AW501036 as the corresponding component for reservoir-fed systems. The reference electrode works together with the sodium electrode, associated cable assembly, wet-section components, sample system and analyzer electronics. Its measurement role therefore depends on correct integration within the complete ASO550 system. The exact operating performance, maintenance procedure and installation requirements should be determined from the applicable ABB ASO550 documentation. For technical records, the recommended identification is ABB AW501035 — ASO550 Reference Electrode for Non-Reservoir-Fed Systems.

ABB AW501035 ASO550 Reference Electrode for Non-Reservoir-Fed Systems

ABB AW501035 is an ASO550 reference electrode designed for non-reservoir-fed systems within ABB sodium measurement applications. The component is listed in ABB documentation as an ASO550 reference electrode for non-reservoir-fed systems and forms part of the wet-section spare-parts configuration for the Navigator 500 sodium analyzer platform. Its primary function is to provide the reference potential required for the electrochemical sodium measurement process.

The complete part number is important when identifying this component because the ASO550 system uses different reference-electrode arrangements depending on the wet-section configuration. ABB specifically distinguishes AW501035 for non-reservoir-fed systems from AW501036 for reservoir-fed systems. This distinction should be retained in technical documentation, maintenance records and component identification. :contentReference[oaicite:1]{index=1}

Product Identification

  • Manufacturer: ABB
  • Part Number: AW501035
  • Product Family: ASO550
  • Associated Platform: Navigator 500
  • Product Type: Reference Electrode
  • Application: Sodium Measurement
  • System Category: Continuous Liquid Analyzer
  • System Configuration: Non-Reservoir-Fed
  • Product Category: Analytical Measurement Spare Part
  • Measurement Technology: Electrochemical Sodium Analysis

ABB ASO550 Reference Electrode

The ABB ASO550 is part of the Navigator 500 sodium analyzer platform used for continuous sodium measurement. Within the analyzer’s wet section, the reference electrode works together with the sodium electrode and associated measurement components to establish the electrical conditions required for electrochemical analysis.

AW501035 is therefore not a general-purpose reference probe. It is specifically associated with the ASO550 configuration and is identified for non-reservoir-fed systems. ABB’s operating instructions place AW501035 and AW501036 in the Navigator 500 sodium wet-section spare-parts list, with the two components serving different system configurations. :contentReference[oaicite:2]{index=2}

Reference Electrode Function

A reference electrode provides a stable electrochemical reference against which the sensing electrode response can be evaluated. In a sodium measurement system, the sodium-sensitive electrode responds to the chemical condition of the sample, while the reference electrode establishes the reference potential needed by the measurement circuit.

This relationship allows the analyzer electronics to interpret the electrochemical response and determine the corresponding sodium measurement. The reference electrode is consequently an important part of the complete measurement chain even though it does not directly measure sodium concentration by itself.

AW501035 should therefore be understood as a supporting measurement component within the ASO550 analytical system rather than as an independent sodium analyzer.

Non-Reservoir-Fed System Configuration

The term “non-reservoir-fed” is one of the most important characteristics of ABB AW501035. It identifies the wet-section configuration for which the reference electrode is intended.

ABB documentation lists AW501035 as the reference electrode for non-reservoir-fed systems and AW501036 as the corresponding reference electrode for reservoir-fed systems. This separation means that the two part numbers should not be treated as interchangeable solely because both are reference electrodes used within the same general ASO550 sodium measurement family. :contentReference[oaicite:3]{index=3}

When identifying a replacement component, the existing analyzer configuration should therefore be established before selecting the reference electrode.

Navigator 500 Sodium Analyzer

The Navigator 500 sodium analyzer is designed for continuous sodium measurement in liquid-analysis applications. The ASO550 measurement arrangement uses a combination of sensing, reference, sample-handling and electronic components to produce the sodium measurement.

AW501035 belongs to the wet-section portion of this analytical architecture. The wet section is where the sample interacts with the relevant measurement components before the electrical measurement signal is processed by the analyzer.

The reference electrode must operate within this complete arrangement to provide the appropriate electrochemical reference for the sodium measurement process.

Sodium Measurement Principle

Sodium analysis is an electrochemical measurement process in which the sodium-sensitive electrode responds to the concentration of sodium ions in the sample. The reference electrode provides the stable reference potential required to evaluate that response.

The analyzer electronics use the electrical relationship between the sensing and reference electrodes to calculate the sodium measurement. The final measurement is therefore dependent on both electrode behavior and the surrounding analytical conditions.

For this reason, an abnormal sodium reading should not automatically be attributed to the sodium electrode alone. The reference electrode, sample conditions, calibration, wiring and analyzer electronics can also influence the measurement.

Relationship Between the Sodium and Reference Electrodes

The sodium electrode and reference electrode perform different but complementary functions. The sodium electrode responds to the target sodium-ion concentration, while the reference electrode provides the stable electrical reference necessary for the electrochemical measurement.

AW501035 is therefore used as part of a paired measurement arrangement within the ASO550 system. Correct operation depends on both electrodes being properly integrated with the analyzer’s wet section and measurement electronics.

The distinction between these components is important when troubleshooting or maintaining a sodium analyzer.

Technical Specification Summary

ParameterABB AW501035
ManufacturerABB
Part NumberAW501035
Product FamilyASO550
Associated AnalyzerNavigator 500
Product TypeReference Electrode
Measurement ApplicationSodium Measurement
System ConfigurationNon-Reservoir-Fed
Application CategoryContinuous Liquid Analysis
Component CategoryAnalytical Measurement Spare Part

Wet-Section Integration

The ASO550 wet section contains the components that interact directly with the sodium analyzer’s sample stream. ABB documentation identifies several related components, including the sodium electrode, reference electrode cable assembly, sodium electrode cable assembly, flowcell assembly and other sample-handling parts.

AW501035 is specifically identified as the reference electrode for the non-reservoir-fed configuration. Its installation and connection therefore need to correspond with the applicable ASO550 wet-section arrangement.

The complete wet-section configuration should be considered when evaluating electrode compatibility, maintenance procedures or measurement problems.

Reference Electrode Cable Connection

The reference electrode is connected to the analyzer through the appropriate reference-electrode connection and cable arrangement. ABB’s spare-parts documentation separately identifies a reference electrode cable assembly, showing that the electrode and cable form distinct components within the analytical system. :contentReference[oaicite:4]{index=4}

When troubleshooting a reference signal, both the electrode and its associated cable connection should therefore be considered. A poor connection or damaged cable can affect the electrical reference even when the electrode itself is functioning correctly.

Electrical connections should be inspected according to the applicable ASO550 installation and maintenance procedures.

Non-Reservoir-Fed Measurement Arrangement

The non-reservoir-fed configuration is an important part of the AW501035 identification. The ASO550 platform supports both non-reservoir-fed and reservoir-fed reference-electrode arrangements, with separate part numbers assigned to the respective configurations.

AW501035 corresponds to the non-reservoir-fed configuration. AW501036 is separately identified for reservoir-fed systems. This difference should be checked before selecting a reference electrode for an existing Navigator 500 installation.

Using the correct system configuration helps ensure that the electrode is mechanically and functionally appropriate for the installed wet section.

Continuous Liquid Analysis

Continuous liquid analysis allows industrial processes to monitor chemical parameters without relying exclusively on occasional manual sampling. Sodium concentration is an important analytical parameter in applications where water chemistry needs to be observed continuously.

The ASO550 system provides the analytical platform, while AW501035 contributes the reference-electrode function required by the electrochemical measurement arrangement.

The resulting measurement can be used as part of a broader process-monitoring strategy, depending on the application and analyzer configuration.

Water Chemistry Monitoring

Sodium analysis can be relevant to industrial water systems where changes in dissolved sodium concentration provide information about water quality or process conditions. Continuous monitoring can help operators observe trends and identify deviations from expected values.

The reference electrode plays an indirect but essential role in this process because the analyzer needs a stable electrochemical reference to interpret the response from the sodium-sensitive electrode.

AW501035 therefore contributes to the measurement reliability of the complete sodium-analysis system rather than producing a sodium value independently.

Calibration Considerations

Calibration is an important part of maintaining accurate analytical measurements. The calibration process establishes the relationship between the electrode response and the expected sodium concentration.

The condition of the reference electrode can influence this relationship because an unstable reference potential can affect the electrical measurement used by the analyzer.

When calibration behavior changes unexpectedly, the reference electrode should be evaluated together with the sodium electrode, calibration solutions, sample conditions and analyzer configuration.

Maintenance Considerations

Maintenance of the AW501035 reference electrode should follow the procedures specified for the ASO550 system. The electrode should be inspected as part of the complete wet-section maintenance process.

The measurement environment, electrode condition and electrical connections can all influence analyzer performance. Maintenance personnel should document the exact part number when replacing or inspecting the reference electrode.

Using the full designation AW501035 helps distinguish the component from the reservoir-fed reference electrode AW501036 and from the ASO550 sodium electrode AW501030.

Troubleshooting Sodium Measurement

If the Navigator 500 sodium analyzer produces an unstable or unexpected measurement, the reference electrode should be considered as one part of the diagnostic process. The sodium electrode, reference electrode, cables, sample flow and analyzer electronics form an interconnected measurement chain.

The first stage of troubleshooting should establish whether the issue is related to the sample conditions or to the analytical measurement hardware. Calibration status and recent maintenance activity can also provide useful information.

If the reference signal is unstable, inspection of AW501035 and its associated cable and connections may be appropriate according to the applicable maintenance procedure.

Compatibility Identification

Compatibility should be established using the complete ABB part number and the system configuration. AW501035 is specifically identified as an ASO550 reference electrode for non-reservoir-fed systems.

This designation should not be shortened to “ASO550 reference electrode” when preparing a spare-parts list because the ASO550 platform includes another reference electrode configuration for reservoir-fed systems.

The analyzer model and wet-section arrangement should therefore be checked before selecting the component.

Difference Between AW501035 and AW501036

ABB documentation provides a clear distinction between two ASO550 reference-electrode part numbers. AW501035 is specified for non-reservoir-fed systems, while AW501036 is specified for reservoir-fed systems.

This distinction is one of the most useful technical identifiers when working with the Navigator 500 sodium analyzer. The two components belong to the same general analytical system but correspond to different wet-section configurations.

For this reason, the existing system configuration should always be confirmed before selecting either reference electrode.

Related ASO550 Components

The ASO550 wet section contains several components that work together with AW501035. ABB documentation lists the sodium electrode AW501030, reference electrode cable assembly 1431880, sodium electrode cable assembly 1048880 and several wet-section mechanical and sample-handling components.

Other listed components include the reservoir-fed electrode upgrade kit AW501037, flowcell assembly AW501056, sodium electrode sleeve and O-ring AW501057, and Pt1000-related assemblies. :contentReference[oaicite:5]{index=5}

These components demonstrate that AW501035 is part of a larger analytical assembly rather than an isolated measurement device.

Engineering Documentation

For an industrial equipment database, the recommended product identification is “ABB AW501035 — ASO550 Reference Electrode for Non-Reservoir-Fed Systems.”

This wording clearly identifies the manufacturer, exact part number, product family, component function and intended wet-section configuration.

Additional documentation can record the associated Navigator 500 analyzer, installation configuration and relevant cable or wet-section components.

Application in Industrial Analysis

The AW501035 reference electrode is relevant to industrial analytical systems where sodium concentration is monitored continuously. Applications can include water chemistry monitoring and other process-analysis environments in which stable electrochemical measurement is required.

The reference electrode contributes to the measurement chain by establishing the electrical reference used by the analyzer. Its performance should therefore be considered in combination with the sample system and sodium electrode.

Correct system configuration remains particularly important because the AW501035 designation is specific to non-reservoir-fed ASO550 systems.

Technical Identification for Maintenance

When recording the component in a maintenance database, the following identification is suitable: ABB AW501035, ASO550 Reference Electrode, Non-Reservoir-Fed System.

The complete part number should be retained in purchase records, equipment documentation and maintenance reports. This prevents confusion with AW501030, the ASO550 sodium electrode, and AW501036, the reference electrode intended for reservoir-fed systems.

Measurement Stability

Stable reference conditions are essential for electrochemical measurement. Because the sodium measurement depends on the potential difference between the sensing and reference electrodes, changes in the reference electrode can influence the analyzer’s measurement behavior.

Measurement stability should therefore be evaluated by considering the complete electrochemical system. Electrode condition, sample quality, calibration and electrical connections all contribute to the final result.

The AW501035 reference electrode provides the reference function required by the applicable non-reservoir-fed ASO550 configuration.

System-Level Compatibility

The most reliable way to evaluate compatibility is to identify the installed analyzer and wet-section configuration first. Once the configuration is established, the appropriate reference-electrode part number can be selected.

For a non-reservoir-fed ASO550 arrangement, ABB documentation identifies AW501035 as the applicable reference electrode. A reservoir-fed arrangement uses the separately identified AW501036 component.

This system-level identification is more reliable than selecting a component based only on appearance or general product-family terminology.

Conclusion

ABB AW501035 is an ASO550 reference electrode for non-reservoir-fed systems within the Navigator 500 sodium analyzer platform. ABB’s operating instructions explicitly list AW501035 as the “ASO550 reference electrode for non reservoir-fed systems” and distinguish it from AW501036 for reservoir-fed systems. :contentReference[oaicite:6]{index=6}

The component provides the reference function required for the electrochemical sodium measurement process. It works together with the ASO550 sodium electrode, associated cable assemblies, sample-handling components and analyzer electronics to establish the conditions needed for sodium measurement.

For technical documentation and component identification, the complete designation “ABB AW501035 — ASO550 Reference Electrode for Non-Reservoir-Fed Systems” should be retained. The non-reservoir-fed configuration is the key characteristic separating this component from the related AW501036 reference electrode for reservoir-fed systems.

重量1.2 磅
尺寸55 × 10 × 58 英寸

评价

目前还没有评价

成为第一个“ABB AW501035 ASO550 Reference Electrode for Non-Reservoir-Fed Sodium Analyzer Systems” 的评价者

您的邮箱地址不会被公开。 必填项已用 * 标注