促销!

ABB 170M4417 Eaton Bussmann Semiconductor Fuse 700A 690V

原价为:$101.00。当前价格为:$71.00。

+ Free Shipping

The 170M4417 is an Eaton Bussmann semiconductor fuse rated at 700 A and 690 V. It is designed for circuit protection in suitable power-electronic applications and is listed in ABB drive documentation for compatible ACS880-104C inverter modules. Correct selection requires verification of the fuse rating, application, mounting arrangement, and equipment-specific requirements.

ABB 170M4417 Eaton Bussmann Semiconductor Fuse 700A 690V

Product Overview

The 170M4417 is an Eaton Bussmann semiconductor protection fuse designed for use in suitable industrial power-electronic applications. It has a rated current of 700 A and a rated voltage of 690 V. The fuse belongs to the 170M series and is used to provide overcurrent protection for compatible electrical circuits. ABB drive hardware documentation also lists this fuse type for specified ACS880-104C inverter module configurations.

Semiconductor devices such as power transistors, diodes, and other converter components can be sensitive to high fault currents. A suitable semiconductor fuse helps limit the energy that passes through a faulted circuit by interrupting excessive current under the conditions specified for the fuse. Its selection is therefore an important part of the protection design for power converters and related electrical equipment.

The 170M4417 should be selected according to the equipment manufacturer’s requirements, the circuit’s operating conditions, and the fuse’s published characteristics. Although the model is associated with ABB drive applications, the component manufacturer is Eaton Bussmann. The fuse should not be treated as a universal replacement for other fuse models with similar current ratings.

Semiconductor Fuse Protection Function

Semiconductor fuses are developed for circuits that contain power-electronic components requiring coordinated protection. In converter equipment, fault current may rise rapidly when a semiconductor device or connected circuit fails. A fuse selected for this duty is intended to interrupt the current in accordance with its specified electrical characteristics and the requirements of the protected equipment.

The protection performance of a fuse depends on more than its nominal current rating. Relevant characteristics include its voltage rating, interrupting capability, time-current behavior, and energy let-through characteristics. The fuse must also be compatible with the prospective fault current and the electrical arrangement in which it is installed.

The 170M4417 is identified as a 700 A, 690 V fuse. These ratings are important starting points for component identification, but they do not independently establish suitability for every 700 A circuit. The application must be checked against the fuse data sheet and the relevant drive or converter documentation.

Application in ABB Drive Systems

ABB documentation for ACS880-104C inverter modules lists the 170M4417 for the 0350A-3 module type. The referenced hardware documentation specifies a 700 A, 690 V fuse and identifies ABB ordering code 64607383 for this application. This association is useful when identifying the fuse required by a compatible drive configuration.

In an inverter system, fuses may be incorporated into power circuits to protect components and limit the effects of electrical faults. The exact circuit location and protection arrangement depend on the drive design. Maintenance personnel should consult the hardware manual for the particular inverter module rather than infer the fuse location from the model number alone.

When replacing a fuse in an ABB drive, confirm the complete fuse type and the equipment-specific ordering information. A substitute with the same nominal current rating may have different voltage, interruption, or energy characteristics. Such differences can affect coordination with the power electronics and other protective devices.

The 170M4417 should only be used in a configuration for which its electrical characteristics and physical arrangement are suitable. The drive manual and fuse manufacturer’s documentation should be treated as the primary references for the final selection.

Key Technical Ratings

The principal identification information for the Eaton Bussmann 170M4417 is summarized below.

  • Manufacturer: Eaton Bussmann
  • Product number: 170M4417
  • Component type: Semiconductor protection fuse
  • Rated current: 700 A
  • Rated voltage: 690 V
  • Product series: 170M
  • Associated ABB ordering code for the cited drive application: 64607383

These details help distinguish the fuse from other members of the 170M family. Other models in the series may have different current ratings, voltage ratings, and application requirements. Before installation, verify the complete designation on the existing component and compare it with the specified part in the equipment documentation.

Selection and Compatibility Considerations

Fuse selection begins with the electrical requirements of the circuit. The rated current must be appropriate for the intended duty, while the rated voltage must be suitable for the circuit’s operating voltage. The fuse’s interrupting capability must also be adequate for the prospective fault current at the installation point.

In power-electronic applications, coordination between the fuse and the protected semiconductor devices is especially important. The fuse’s clearing behavior and energy let-through characteristics should be evaluated against the equipment manufacturer’s protection design. Selecting a component based only on its current rating can result in inadequate protection or an incompatible installation.

Physical compatibility must also be confirmed. Check the fuse dimensions, mounting arrangement, terminal interfaces, and any specified hardware. A fuse that has the correct nominal ratings may still be unsuitable if its mechanical configuration differs from the original design.

For ABB drive equipment, use the correct hardware manual and ordering code for the specific inverter module. Confirm whether the fuse is specified as a single component or as part of a larger assembly, and follow the manufacturer’s instructions for any associated mounting or connection components.

Installation and Replacement

Installation and replacement should be performed by qualified personnel using the approved electrical safety procedures for the equipment. Before accessing the fuse, isolate the equipment from its power sources and follow the manufacturer’s discharge and verification procedures. Drive systems may contain stored electrical energy after the incoming supply has been disconnected.

Never remove or install a fuse while the circuit is energized. Confirm that the equipment has reached the safe state specified by the manufacturer before beginning work. Use appropriate tools and protective measures, and observe the site procedures for electrical work.

Before installing the replacement, compare its complete designation with the specified part number. Inspect the fuse mounting area and associated connections for signs of overheating, damage, contamination, or loose hardware. Follow the equipment instructions for installation orientation, tightening requirements, and any required inspection steps.

After replacement, verify that the assembly is complete and that all required covers and protective barriers are restored. The equipment should be returned to service only in accordance with the approved commissioning and maintenance procedure.

Maintenance and Troubleshooting

A fuse that has operated should be treated as an indication that an overcurrent event may have occurred. Simply replacing the fuse without investigating the underlying condition can lead to repeated failures or additional equipment damage. Maintenance personnel should review the drive’s fault history and examine the affected power circuit in accordance with the manufacturer’s troubleshooting instructions.

Potential causes may include a fault in a power semiconductor, a short circuit, damaged insulation, wiring problems, or another abnormal operating condition. The actual cause must be established through an appropriate diagnostic process. The fuse itself should not be bypassed or replaced with a component of an unapproved rating to keep the equipment running.

During planned maintenance, follow the inspection and replacement guidance specified for the equipment. Check the component identification and the condition of the surrounding assembly. Record the fuse model, the associated equipment, and the reason for replacement in the maintenance history to support later fault analysis.

Identification and Spare Parts Management

Accurate identification is important when managing semiconductor fuses for industrial drive systems. The product number 170M4417 should be recorded together with the manufacturer and the associated equipment designation. For the ABB application cited in the hardware manual, ordering code 64607383 provides an additional reference for parts identification.

Maintenance records should distinguish between the fuse’s manufacturer part number and any equipment manufacturer’s ordering code. Keeping both identifiers available can simplify searches in parts catalogs and reduce the risk of confusing the fuse with a similar model. Where multiple drive types are installed, record the relevant module type and the applicable manual reference alongside the part number.

Before approving a substitute, compare the proposed component’s electrical characteristics, physical arrangement, and protection behavior with the original specification. Any replacement decision should comply with the equipment manufacturer’s requirements and the design of the protected circuit.

Conclusion

The Eaton Bussmann 170M4417 is a 700 A, 690 V semiconductor protection fuse used in suitable power-electronic applications. ABB documentation identifies it for a specified ACS880-104C inverter module configuration and associates that application with ABB ordering code 64607383.

Correct application requires more than matching the nominal current rating. Engineers and maintenance personnel should verify voltage rating, interruption capability, protection coordination, mechanical compatibility, and the requirements of the specific drive system. Following the applicable ABB and Eaton Bussmann documentation supports accurate component identification and appropriate circuit protection.

重量0.35 磅
尺寸6 × 5 × 6.2 英寸

评价

目前还没有评价

成为第一个“ABB 170M4417 Eaton Bussmann Semiconductor Fuse 700A 690V” 的评价者